- `timescale 1ns/1ps
- module pwm_control_demo (
- input wire clk,
- input wire reset_n,
- // Control command: -128 .. +127
- input wire signed [7:0] cmd,
- // Safety/control signals
- input wire enable,
- input wire fault,
- // Observable internal results
- output reg signed [7:0] limited_cmd,
- output reg direction,
- output reg [6:0] duty,
- // Actual PWM waveform
- output wire pwm_out
- );
- // 0..99 PWM carrier counter
- reg [6:0] pwm_counter;
- // ---------------------------------------------------------
- // 1. Saturation limiter: command limited to -90 .. +90
- // 2. Sign -> direction
- // 3. Absolute value -> PWM duty
- // ---------------------------------------------------------
- always @(*) begin
- if (cmd > 8'sd90)
- limited_cmd = 8'sd90;
- else if (cmd < -8'sd90)
- limited_cmd = -8'sd90;
- else
- limited_cmd = cmd;
- if (limited_cmd < 0) begin
- direction = 1'b1; // reverse
- duty = -limited_cmd;
- end else begin
- direction = 1'b0; // forward
- duty = limited_cmd;
- end
- end
- // ---------------------------------------------------------
- // PWM carrier: 0,1,2 ... 99,0,1...
- // ---------------------------------------------------------
- always @(posedge clk or negedge reset_n) begin
- if (!reset_n)
- pwm_counter <= 7'd0;
- else if (pwm_counter == 7'd99)
- pwm_counter <= 7'd0;
- else
- pwm_counter <= pwm_counter + 1'b1;
- end
- // ---------------------------------------------------------
- // PWM output
- //
- // duty=25 -> 25 high clocks / 100 clocks = 25%
- //
- // enable=0 or fault=1 -> PWM forced OFF
- // ---------------------------------------------------------
- assign pwm_out =
- reset_n &&
- enable &&
- !fault &&
- (pwm_counter < duty);
- endmodule